Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Manual Flow Dynamics Calibration - Message informing about historic data storaf #4168

Closed
2 tasks done
JDPS opened this issue May 28, 2024 · 6 comments
Closed
2 tasks done
Assignees
Labels
bug Something isn't working

Comments

@JDPS
Copy link

JDPS commented May 28, 2024

Bambu Studio Version

1.9.1.66

Where is the application from?

Bambu Lab Official website

OS version

Windows 11

Additional system information

CPU :Intel Core i5-9600K
MB: MSI Z390-A PRO (MS-7B98)
RAM: 48Gb 2xF4-3000C16-16GISB + 2xF4-3000C8-8GISB
GPU: GIGABYTE GTX 1660 SUPER OC 6G (GV-N166SOC-6GD)
HD: Samsung SSD 970 EVO Plus 1TB

Printer

Bambu Lab X1 Carbon Combo

How to reproduce

  1. Select (left mouse click) the Calibration Tab on the top bar.
  2. Select (left mouse click) flow dynamics on the left bar;
  3. Select (left mouse click) the manual calibration button;
  4. Select (left mouse click) the calibration button;

Actual results

Receive a pop-up message with the following content:

"This machine type can only hold 16 historical results per nozzle. You can delete the existing
historical results and then start calibration. Or you can continue the calibration, but you cannot
create new calibration historical results.
Do you still want to continue the calibration?"
image

If I proceed, the process will work as expected, but the message will seem pointless and incorrect.

Expected results

Start the calibration procedure without any pop-up message.

Project file & Debug log uploads

log.zip
I am not doing any project.

Checklist of files to include

  • Log file
  • Project file
@JDPS JDPS added the bug Something isn't working label May 28, 2024
@zhimin-zeng-bambulab
Copy link
Collaborator

@JDPS
This message prompts you that you cannot store new calibration values ​​in the management table.
If you choose to calibrate, you can continue, but your calibration values ​​will not be stored in the management list.

@JDPS
Copy link
Author

JDPS commented May 29, 2024

@zhimin-zeng-bambulab, many thanks for the swift answer.
I found this issue after a user complaint in the BL forum.
I could indeed replicate and got the same message, but something doesn't seem right:

  • I have at least double the k-values memorised in the management table for the 0.4mm nozzle.
  • If I choose the auto flow dynamics calibration, no alert message will be shown, and the new values will be added to the table.
  • Within the management table, I can press the "new" button to successfully add a new filament and respective k-value without any alert.

The alert message seems exclusive to the manual calibration procedure.
Additionally, I successfully saved the new filament calibration values by ignoring the alert and continuing with the calibration procedure. I did it three times.

To ensure we are discussing the same thing, I assume the "calibration management table" relates to the table shown when one selects the option "manage results". Correct?

Thank you.

@zhimin-zeng-bambulab
Copy link
Collaborator

@JDPS Thanks for your patient explanation. X1C should not have this restriction. This is a BUG. We will fix it. Thanks!

@JDPS
Copy link
Author

JDPS commented May 29, 2024

Thanks for the clarification, and I'm glad it can help.

@zhimin-zeng-bambulab
Copy link
Collaborator

@JDPS We will notify you here when the fixed version comes out

@zhimin-zeng-bambulab
Copy link
Collaborator

@JDPS It has been fixed in v01.09.02.57, please have a try.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
bug Something isn't working
Projects
None yet
Development

No branches or pull requests

3 participants