Notifications
You must be signed in to change notification settings - Fork 7
/
Copy pathaquamonitor-1.8.py
157 lines (142 loc) · 7.42 KB
/
aquamonitor-1.8.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
#!/usr/bin/python
import sys, time, httplib, urllib, urllib2, logging, RPi.GPIO as GPIO, os.path, os, traceback, signal, pygame, syslog
from subprocess import call, Popen, PIPE
from datetime import datetime, timedelta
Alarms={"WATER_LEAK_DETECTOR_1":0,"WATER_LEAK_DETECTOR_2":0,"FLOATSW_HIGH_WL":0,"FLOATSW_LOW_WL":0} # Alarm flags dictionary
Pins={"WATER_LEAK_DETECTOR_1":24,"WATER_LEAK_DETECTOR_2":23,"FLOATSW_HIGH_WL":26,"FLOATSW_LOW_WL":19} # GPIO Pins mapping
PUSHOVER_TOKEN = "[YOUR APP ID]" # your Pushover APP toker
PUSHOVER_USER = "[YOUR TOKEN]" # your Pushover USER token
LOOP_WAIT_TIMER = 16 # defines how many seconds interval between polling
VERSION = 1.8 # Code version number
CAM_URL = "http://123.200.100.99:9091" # Camera URL
REPEAT_TIMER = 10
def Audio_alarm():
try:
pygame.mixer.init()
pygame.mixer.music.load("/usr/local/python/Aquamonitor/alarm.mp3")
pygame.mixer.music.play()
while pygame.mixer.music.get_busy() == True:
continue
except:
Alert("Cannot play alarm wave file.")
Pass
def Setup():
GPIO.setwarnings(False)
GPIO.setmode(GPIO.BCM)
GPIO.setup(Pins["FLOATSW_HIGH_WL"], GPIO.IN, pull_up_down=GPIO.PUD_UP)
GPIO.setup(Pins["FLOATSW_LOW_WL"], GPIO.IN, pull_up_down=GPIO.PUD_UP)
GPIO.setup(Pins["WATER_LEAK_DETECTOR_1"], GPIO.IN, pull_up_down=GPIO.PUD_UP)
GPIO.setup(Pins["WATER_LEAK_DETECTOR_2"], GPIO.IN, pull_up_down=GPIO.PUD_UP)
if not sys.stdout.isatty(): # if we are not running from console, redirect the stdout & err to files
sys.stdout = open('/var/log/aquamonitor_stdout.log', 'a')
sys.stderr = open('/var/log/aquamonitor_stderr.log','a')
def Time():
return time.strftime("%D %H:%M:%S: ")
def Send_pushover(pushover_content):
try:
conn = httplib.HTTPSConnection("api.pushover.net:443")
conn.request("POST", "/1/messages.json",
urllib.urlencode({
"token": PUSHOVER_TOKEN,
"user": PUSHOVER_USER,
"message": pushover_content,
}),
{ "Content-type": "application/x-www-form-urlencoded" }
)
conn.getresponse()
except:
print(Time() + "could not send pushover alert, passing")
pass
def Refilling():
try:
response = urllib2.urlopen("http://192.168.0.150/set.cmd?user=admin+pass=12345678+cmd=getpower", timeout = 10)
time.sleep(5)
content = response.read()
i = content[10]
if int(i) == 1:
return True
else:
return False
except urllib2.URLError as e:
print(Time() + "could not check IP power plug state, passing: " + str(e))
Send_alert("Cannot communicate with valve: " + str(e), syslog.LOG_ERR)
pass
def Close_RODI():
try:
urllib2.urlopen("http://192.168.0.150/set.cmd?user=admin+pass=12345678+cmd=setpower+p61=0", timeout = 15)
time.sleep(5)
except urllib2.URLError as e:
Send_alert("Cannot communicate with valve: " + type(e), syslog.LOG_ERR)
def Send_alert(message, level):
syslog.syslog(level,message)
Send_pushover(message)
print(Time() + message)
def Repeat_alert(probe, message, timer):
global Alarms
if datetime.now() > Alarms[probe] + timedelta(minutes=timer):
Send_alert(message,syslog.LOG_WARNING)
Alarms[probe] = datetime.now() # reset alarm timestamp to reset the counter for next iteration
def Alert(message, probe): # In any event of an alert, inform through log, mail & pushover
global Alarms
Alarms[probe] = datetime.now() # set a timestamp for recurring alarm cooldown and alert
if probe == "WATER_LEAK_DETECTOR_1" or probe == "WATER_LEAK_DETECTOR_2":
Send_alert(message,syslog.LOG_EMERG)
elif probe == "FLOATSW_HIGH_WL":
Send_alert(message,syslog.LOG_ERR)
elif probe == "FLOATSW_LOW_WL":
Send_alert(message,syslog.LOG_NOTICE)
def Monitor_probe(probe, mesg):
global Alarms
if GPIO.input(Pins[probe]) == 0 and Alarms[probe] == 0: # An alert is detected, for the first time on this probe: alarm + actions
Alert(mesg, probe) # Send the initial Alert
if probe == "WATER_LEAK_DETECTOR_1" or probe == "WATER_LEAK_DETECTOR_2":
Audio_alarm()
if Refilling() == True:
Alert(mesg + " RO/DI valve was opened, closing it.", probe)
Close_RODI()
else:
Alert(mesg, probe)
if probe == "FLOATSW_LOW_WL" and Refilling() == False:
proc = Popen(['python', '/usr/local/python/Aquamonitor/rodi.py', str(600)])
Alert("Refilling for 600 seconds", probe) # by refilling
if probe == "FLOATSW_HIGH_WL": # or by stopping the current refill, if need be
if Refilling() == False:
Alert(mesg, probe)
else:
Close_RODI()
Alert(mesg + " stopping the current refill. ", probe)
elif GPIO.input(Pins[probe]) == 0 and Alarms[probe] !=0: # if alarms continues, we already took actions, so just inform every X minutes
Repeat_alert(probe, "Repeated: " + mesg, REPEAT_TIMER)
elif GPIO.input(Pins[probe]) == 1 and Alarms[probe] !=0: # If we have no longer an alert on the pin but have a not yet cleared alarm
Alert(mesg + " stopped", probe) # tell all is back to normal
Alarms[probe] = 0 # clear the alarm flag
class GracefulKiller:
kill_now = False
def __init__(self):
signal.signal(signal.SIGINT, self.exit_gracefully)
signal.signal(signal.SIGTERM, self.exit_gracefully)
def exit_gracefully(self,signum, frame):
self.kill_now = True
if sys.argv[1] == "start":
Setup()
killer = GracefulKiller()
Send_alert("Starting Aquamonitor v" + str(VERSION) + " continuous monitoring.",syslog.LOG_NOTICE) # Tell the user we (re)started
while True: # Good old infinite loop, what would we be without them?
Monitor_probe("WATER_LEAK_DETECTOR_1","Water leak near RO/DI " + str(CAM_URL)) # Monitor the various probes and react accordingly
Monitor_probe("WATER_LEAK_DETECTOR_2","Water leak under the tank " + str(CAM_URL))
Monitor_probe("FLOATSW_LOW_WL","Low water level in the sump " + str(CAM_URL))
Monitor_probe("FLOATSW_HIGH_WL","High water level in the sump " + str(CAM_URL))
time.sleep(LOOP_WAIT_TIMER) # Execute loop only every minute to lower CPU footprint
if killer.kill_now:
Send_alert("Caught a SIGINT or SIGTERM, exiting cleanly",syslog.LOG_NOTICE)
Close_RODI()
GPIO.cleanup()
sys.exit(3)
else:
print(Time() + "Too few argument provided or start not mentionned")
sys.exit(2)
# Exit code
# 0 : Normal exit
# 1 : Keyboard CTRL+C exit
# 2 : Incorrect argument provided