You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
In the attached file the drainage mat is 100 mm, the void fraction is 0.5 and the percent saturated is 50 percent. The initial storage should be 100 * 0.5 * 0.5 or 25 mm. It is listed as 50 mm as the storage depth is set equal to drainage mat depth as explained on OpenSWMM
As discussed on OpenSWMM.ORG https://www.openswmm.org/Topic/32892/initial-storage-by-lid-summary-results the three layer Green Roof of SWMM5 seems to count the volume in the lower layer or Drainage Mat Twice.
In the attached file the drainage mat is 100 mm, the void fraction is 0.5 and the percent saturated is 50 percent. The initial storage should be 100 * 0.5 * 0.5 or 25 mm. It is listed as 50 mm as the storage depth is set equal to drainage mat depth as explained on OpenSWMM
SWMM_Erica Orsi.inp.txt
the value for initial and final storage of the Green Roof should not include the Drainage Mat twice.
The text was updated successfully, but these errors were encountered: