Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[Bug] No popup after drawing calibration line on viewer-dev.ohif.org #3724

Closed
jbocce opened this issue Oct 13, 2023 · 0 comments · Fixed by #3736
Closed

[Bug] No popup after drawing calibration line on viewer-dev.ohif.org #3724

jbocce opened this issue Oct 13, 2023 · 0 comments · Fixed by #3736
Assignees
Labels
Bugs Bug reported, reproducible, and verified.

Comments

@jbocce
Copy link
Collaborator

jbocce commented Oct 13, 2023

Describe the Bug

After drawing the line for the calibration tool, no popup is displayed to prompt for the length of the line drawn. However this is only occurs with the demo servers viewer-dev.ohif.org and viewer.ohif.org. Using localhost:3000 the tool works correctly.

Steps to Reproduce

  1. Navigate to one of the demo servers
  2. View a study.
  3. Select the calibration tool and draw a line.

The current behavior

No popup prompting for the length of the line drawn.

The expected behavior

Popup prompting for the length of the line drawn.

OS

Windows 11

Node version

18.16.1

Browser

Chrome 117.0.5938.152

@jbocce jbocce added Awaiting Reproduction Can we reproduce the reported bug? Bugs Bug reported, reproducible, and verified. and removed Awaiting Reproduction Can we reproduce the reported bug? labels Oct 13, 2023