Skip to content

Latest commit

 

History

History

pwm2

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 
 
 

PWM 2 Click

PWM 2 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.


Click Library

  • Author : MikroE Team
  • Date : Feb 2020.
  • Type : PWM type

Software Support

Example Description

This application send the PWM signal in one or more outputs.

Example Libraries

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Pwm2

Example Key Functions

  • pwm2_cfg_setup Config Object Initialization function.
void pwm2_cfg_setup ( pwm2_cfg_t *cfg );
  • pwm2_init Initialization function.
err_t pwm2_init ( pwm2_t *ctx, pwm2_cfg_t *cfg );
  • pwm2_set_channel Set channel function.
uint8_t pwm2_set_channel ( pwm2_t *ctx, uint8_t n_channel, uint16_t width, uint8_t correction );
  • pwm2_pwm_start Start PWM module.
void pwm2_pwm_start ( pwm2_t *ctx );
  • void send_output_enable_frame Enable frame.
static void send_output_enable_frame ( pwm2_t *ctx );

Application Init

Configures the Click board and sets all PWM channels on the Click board to 50% duty cycle with the phase shift enabled.

void application_init ( void )
{
    pwm2_cfg_t cfg;

    //  Click initialization.

    pwm2_cfg_setup( &cfg );
    PWM2_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    pwm2_init( &pwm2, &cfg );
    
    pwm2_set_duty_cycle( &pwm2, 0.5 );
    pwm2_pwm_start( &pwm2 );

    pwm2_default_cfg( &pwm2 );
    pwm2_toggle_phase_shift( &pwm2 );

    //setting all 48 PWM channels of the PWM2 Click to 50% duty
    for( uint8_t cnt = 1; cnt < 49; cnt++ ) 
    {
        pwm2_set_channel( &pwm2, cnt, PWM2_50_PERCENT_DUTY, PWM2_NO_CORRECTION );
    }
}

Application Task

The first 10 PWM channels of PWM2 Click board are switched back and forth from 25% duty cycle to 75% duty cycle every 10 seconds.

void application_task ( void )
{
    for ( uint8_t cnt = 1; cnt < 10; cnt++ )
    { 
        pwm2_set_channel( &pwm2, cnt, PWM2_25_PERCENT_DUTY, PWM2_NO_CORRECTION );
    }
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    
    for ( uint8_t cnt = 1; cnt < 10; cnt++ )
    { 
        pwm2_set_channel( &pwm2, cnt, PWM2_75_PERCENT_DUTY, PWM2_NO_CORRECTION );
    }
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
}

Application Output

This Click board can be interfaced and monitored in two ways:

  • Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
  • UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.

Additional Notes and Information

The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.