Issue adding new Thaleos radiator valve TS0601 vendor: '_TZE200_rv6iuyxb' #8062
Comments
I checked my model is TRV06 from this doc https://thaleos.com/wp-content/uploads/2024/06/Catalogue-Thaleos-Thermostat-Connecte-20.pdf. So I updated script to similaire data from tuya.js, but still not working :const legacy = require('zigbee-herdsman-converters/lib/legacy');
const fz = {...require('zigbee-herdsman-converters/converters/fromZigbee'), legacy: require('zigbee-herdsman-converters/lib/legacy').fromZigbee};
const tz = {...require('zigbee-herdsman-converters/converters/toZigbee'), legacy: require('zigbee-herdsman-converters/lib/legacy').toZigbee};
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const ota = require('zigbee-herdsman-converters/lib/ota');
const utils = require('zigbee-herdsman-converters/lib/utils');
const globalStore = require('zigbee-herdsman-converters/lib/store');
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const e = exposes.presets;
const ea = exposes.access;
const definition = {
zigbeeModel: ['TS0601'],
fingerprint: [
{modelID: 'TS0601', manufacturerName: '_TZE200_rv6iuyxb'}, //Thaleos Connect
],
model: 'TS0601_thermostat_3',
vendor: 'Tuya',
description: 'Thermostatic radiator valve',
fromZigbee: [tuya.fz.datapoints],
toZigbee: [tuya.tz.datapoints],
whiteLabel: [
tuya.whitelabel('AVATTO', 'ME167', 'Thermostatic radiator valve', ['_TZE200_bvu2wnxz', '_TZE200_6rdj8dzm']),
tuya.whitelabel('AVATTO', 'ME168', 'Thermostatic radiator valve', ['_TZE200_p3dbf6qs', '_TZE200_rxntag7i']),
tuya.whitelabel('EARU', 'TRV06', 'Smart thermostat module', ['_TZE200_yqgbrdyo', '_TZE200_rxq4iti9']),
tuya.whitelabel('AVATTO', 'TRV06', 'Smart thermostat module', ['_TZE200_rv6iuyxb']),
],
onEvent: tuya.onEventSetTime,
configure: tuya.configureMagicPacket,
exposes: [
e.child_lock(),
e.battery_low(),
e
.climate()
.withSetpoint('current_heating_setpoint', 5, 35, 1, ea.STATE_SET)
.withLocalTemperature(ea.STATE)
.withSystemMode(['auto', 'heat', 'off'], ea.STATE_SET)
.withRunningState(['idle', 'heat'], ea.STATE)
.withLocalTemperatureCalibration(-9, 9, 1, ea.STATE_SET),
...tuya.exposes.scheduleAllDays(ea.STATE_SET, 'HH:MM/C HH:MM/C HH:MM/C HH:MM/C HH:MM/C HH:MM/C'),
e
.binary('scale_protection', ea.STATE_SET, 'ON', 'OFF')
.withDescription(
'If the heat sink is not fully opened within ' +
'two weeks or is not used for a long time, the valve will be blocked due to silting up and the heat sink will not be ' +
'able to be used. To ensure normal use of the heat sink, the controller will automatically open the valve fully every ' +
'two weeks. It will run for 30 seconds per time with the screen displaying "Ad", then return to its normal working state ' +
'again.',
),
e
.binary('frost_protection', ea.STATE_SET, 'ON', 'OFF')
.withDescription(
'When the room temperature is lower than 5 °C, the valve opens; when the temperature rises to 8 °C, the valve closes.',
),
e.numeric('error', ea.STATE).withDescription('If NTC is damaged, "Er" will be on the TRV display.'),
],
meta: {
tuyaDatapoints: [
[2, 'system_mode', tuya.valueConverterBasic.lookup({auto: tuya.enum(0), heat: tuya.enum(1), off: tuya.enum(2)})],
[3, 'running_state', tuya.valueConverterBasic.lookup({heat: tuya.enum(0), idle: tuya.enum(1)})],
[4, 'current_heating_setpoint', tuya.valueConverter.divideBy10],
[5, 'local_temperature', tuya.valueConverter.divideBy10],
[7, 'child_lock', tuya.valueConverter.lockUnlock],
[28, 'schedule_monday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(1)],
[29, 'schedule_tuesday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(2)],
[30, 'schedule_wednesday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(3)],
[31, 'schedule_thursday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(4)],
[32, 'schedule_friday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(5)],
[33, 'schedule_saturday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(6)],
[34, 'schedule_sunday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(7)],
[35, null, tuya.valueConverter.errorOrBatteryLow],
[36, 'frost_protection', tuya.valueConverter.onOff],
[39, 'scale_protection', tuya.valueConverter.onOff],
[47, 'local_temperature_calibration', tuya.valueConverter.localTempCalibration2],
],
},
};
module.exports = definition; |
OK, I got a external_converters path issues, IDK why it doesn't work I specified directly in const legacy = require('zigbee-herdsman-converters/lib/legacy');
const fz = {...require('zigbee-herdsman-converters/converters/fromZigbee'), legacy: require('zigbee-herdsman-converters/lib/legacy').fromZigbee};
const tz = {...require('zigbee-herdsman-converters/converters/toZigbee'), legacy: require('zigbee-herdsman-converters/lib/legacy').toZigbee};
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const ota = require('zigbee-herdsman-converters/lib/ota');
const utils = require('zigbee-herdsman-converters/lib/utils');
const globalStore = require('zigbee-herdsman-converters/lib/store');
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const e = exposes.presets;
const ea = exposes.access;
const definition = {
zigbeeModel: ['v6iuyxb'],
fingerprint: [
{modelID: 'TS0601', manufacturerName: '_TZE200_rv6iuyxb'}, //Thaleos Connect
],
model: 'TS0601_thermostat_3',
vendor: 'Tuya',
description: 'Thermostatic radiator valve',
fromZigbee: [tuya.fz.datapoints],
toZigbee: [tuya.tz.datapoints],
whiteLabel: [
tuya.whitelabel('AVATTO', 'TRV06', 'Smart thermostat module', ['_TZE200_rv6iuyxb']),
],
onEvent: tuya.onEventSetTime,
configure: tuya.configureMagicPacket,
exposes: [
e.child_lock(),
e.battery_low(),
e
.climate()
.withSetpoint('current_heating_setpoint', 5, 35, 1, ea.STATE_SET)
.withLocalTemperature(ea.STATE)
.withSystemMode(['auto', 'heat', 'off'], ea.STATE_SET)
.withRunningState(['idle', 'heat'], ea.STATE)
.withLocalTemperatureCalibration(-9, 9, 1, ea.STATE_SET),
...tuya.exposes.scheduleAllDays(ea.STATE_SET, 'HH:MM/C HH:MM/C HH:MM/C HH:MM/C HH:MM/C HH:MM/C'),
e
.binary('scale_protection', ea.STATE_SET, 'ON', 'OFF')
.withDescription(
'If the heat sink is not fully opened within ' +
'two weeks or is not used for a long time, the valve will be blocked due to silting up and the heat sink will not be ' +
'able to be used. To ensure normal use of the heat sink, the controller will automatically open the valve fully every ' +
'two weeks. It will run for 30 seconds per time with the screen displaying "Ad", then return to its normal working state ' +
'again.',
),
e
.binary('frost_protection', ea.STATE_SET, 'ON', 'OFF')
.withDescription(
'When the room temperature is lower than 5 °C, the valve opens; when the temperature rises to 8 °C, the valve closes.',
),
e.numeric('error', ea.STATE).withDescription('If NTC is damaged, "Er" will be on the TRV display.'),
],
meta: {
tuyaDatapoints: [
[2, 'system_mode', tuya.valueConverterBasic.lookup({auto: tuya.enum(0), heat: tuya.enum(1), off: tuya.enum(2)})],
[3, 'running_state', tuya.valueConverterBasic.lookup({heat: tuya.enum(0), idle: tuya.enum(1)})],
[4, 'current_heating_setpoint', tuya.valueConverter.divideBy10],
[5, 'local_temperature', tuya.valueConverter.divideBy10],
[7, 'child_lock', tuya.valueConverter.lockUnlock],
[28, 'schedule_monday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(1)],
[29, 'schedule_tuesday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(2)],
[30, 'schedule_wednesday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(3)],
[31, 'schedule_thursday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(4)],
[32, 'schedule_friday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(5)],
[33, 'schedule_saturday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(6)],
[34, 'schedule_sunday', tuya.valueConverter.thermostatScheduleDayMultiDPWithDayNumber(7)],
[35, null, tuya.valueConverter.errorOrBatteryLow],
[36, 'frost_protection', tuya.valueConverter.onOff],
[39, 'scale_protection', tuya.valueConverter.onOff],
[47, 'local_temperature_calibration', tuya.valueConverter.localTempCalibration2],
],
},
};
module.exports = definition; State : {
"battery_low": false,
"child_lock": "UNLOCK",
"current_heating_setpoint": 19,
"frost_protection": "ON",
"linkquality": 180,
"local_temperature": 21,
"local_temperature_calibration": 3,
"running_state": "idle",
"scale_protection": "OFF",
"schedule_friday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"schedule_monday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"schedule_saturday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"schedule_sunday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"schedule_thursday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"schedule_tuesday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"schedule_wednesday": "06:00/21.0 08:00/16.0 12:00/21.0 14:00/16.0",
"system_mode": "auto"
} But documentation says it also could detect windows open/close state. I think it would be nice to add too, so I will work on later this week. Can somebody help me to understand : tuyaDatapoints and tuya.valueConverters ... ? |
Hi @kostya-fr , thanks for the configuration you provided, i can confirm that's working well on my instance too. zigbeeModel: ['TS0601'],
model: 'TS0601',
vendor: '_TZE200_ow09xlxm', Probably the vendor suffix is kinda random. Idk if it's possible to support Anyway, thanks :) |
I just got AVATTO TRV06 radiator valves, they reported as "unsupported" in my z2m (1.40.2) and managed to get them working thanks to @kostya-fr external converter.
The only change I made was the @martinbonneau it looks like the vendor suffix is somewhat random. |
I received an ATTO ME167 that looks like the Thaleos TRV06-AT from above. z2m 1.41.0 is sadly not successfully detecting it and thinks it's a TS0601. external definition: const definition = {
zigbeeModel: ['TS0601'],
model: 'TS0601',
vendor: '_TZE200_9xfjixap',
description: 'Automatically generated definition',
extend: [],
meta: {},
};
module.exports = definition; Optical representation of the actual device: |
It's also working for "TZE204_ogx8u5z6"! Thanks! |
Hello,
I got same French valves by Thaleos-Connect, I have following definition :
I added following code (from #7998) into /config/zigbee2mqtt/TS0601.js :
after restarting zigbee2mqtt and adding device I keep message :
Originally posted by @kostya-fr in #7998 (comment)
The text was updated successfully, but these errors were encountered: