forked from Zero-Grav/ERCF-Software-V3
-
Notifications
You must be signed in to change notification settings - Fork 0
/
install.sh
executable file
·724 lines (668 loc) · 29.9 KB
/
install.sh
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
#!/bin/bash
# Happy Hare ERCF Software
# Installer
#
# Copyright (C) 2022 moggieuk#6538 (discord) moggieuk@hotmail.com
#
KLIPPER_HOME="${HOME}/klipper"
KLIPPER_CONFIG_HOME="${HOME}/klipper_config"
PRINTER_DATA_CONFIG_HOME="${HOME}/printer_data/config"
declare -A PIN 2>/dev/null || {
echo "Please run this script with ./bash $0"
exit 1
}
# Pins for Fysetc Burrows ERB board, ERCF EASY-BRD and ERCF EASY-BRD with Seed Studio XIAO RP2040
PIN[ERB,gear_uart_pin]="ercf:gpio20"; PIN[EASY-BRD,gear_uart_pin]="ercf:PA8"; PIN[EASY-BRD-RP2040,gear_uart_pin]="ercf:gpio6"
PIN[ERB,gear_step_pin]="ercf:gpio10"; PIN[EASY-BRD,gear_step_pin]="ercf:PA4"; PIN[EASY-BRD-RP2040,gear_step_pin]="ercf:gpio27"
PIN[ERB,gear_dir_pin]="!ercf:gpio9"; PIN[EASY-BRD,gear_dir_pin]="!ercf:PA10"; PIN[EASY-BRD-RP2040,gear_dir_pin]="!ercf:gpio28"
PIN[ERB,gear_enable_pin]="!ercf:gpio8"; PIN[EASY-BRD,gear_enable_pin]="!ercf:PA2"; PIN[EASY-BRD-RP2040,gear_enable_pin]="!ercf:gpio26"
PIN[ERB,gear_diag_pin]="ercf:gpio13"; PIN[EASY-BRD,gear_diag_pin]=""; PIN[EASY-BRD-RP2040,gear_diag_pin]=""
PIN[ERB,gear_endstop_pin]="ercf:gpio24"; PIN[EASY-BRD,gear_endstop_pin]="ercf:PB9"; PIN[EASY-BRD-RP2040,gear_endstop_pin]="ercf:gpio1"
PIN[ERB,selector_uart_pin]="ercf:gpio17"; PIN[EASY-BRD,selector_uart_pin]="ercf:PA8"; PIN[EASY-BRD-RP2040,selector_uart_pin]="ercf:gpio6"
PIN[ERB,selector_step_pin]="ercf:gpio16"; PIN[EASY-BRD,selector_step_pin]="ercf:PA9"; PIN[EASY-BRD-RP2040,selector_step_pin]="ercf:gpio7"
PIN[ERB,selector_dir_pin]="!ercf:gpio15"; PIN[EASY-BRD,selector_dir_pin]="!ercf:PB8"; PIN[EASY-BRD-RP2040,selector_dir_pin]="!ercf:gpio0"
PIN[ERB,selector_enable_pin]="!ercf:gpio14"; PIN[EASY-BRD,selector_enable_pin]="!ercf:PA11"; PIN[EASY-BRD-RP2040,selector_enable_pin]="!ercf:gpio29"
PIN[ERB,selector_diag_pin]="ercf:gpio19"; PIN[EASY-BRD,selector_diag_pin]="ercf:PA7"; PIN[EASY-BRD-RP2040,selector_diag_pin]="ercf:gpio2"
PIN[ERB,selector_endstop_pin]="ercf:gpio24"; PIN[EASY-BRD,selector_endstop_pin]="ercf:PB9"; PIN[EASY-BRD-RP2040,selector_endstop_pin]="ercf:gpio1"
PIN[ERB,servo_pin]="ercf:gpio23"; PIN[EASY-BRD,servo_pin]="ercf:PA5"; PIN[EASY-BRD-RP2040,servo_pin]="ercf:gpio4"
PIN[ERB,encoder_pin]="ercf:gpio22"; PIN[EASY-BRD,encoder_pin]="ercf:PA6"; PIN[EASY-BRD-RP2040,encoder_pin]="ercf:gpio3"
# Screen Colors
OFF='\033[0m' # Text Reset
BLACK='\033[0;30m' # Black
RED='\033[0;31m' # Red
GREEN='\033[0;32m' # Green
YELLOW='\033[0;33m' # Yellow
BLUE='\033[0;34m' # Blue
PURPLE='\033[0;35m' # Purple
CYAN='\033[0;36m' # Cyan
WHITE='\033[0;37m' # White
B_RED='\033[1;31m' # Bold Red
B_GREEN='\033[1;32m' # Bold Green
B_YELLOW='\033[1;33m' # Bold Yellow
B_CYAN='\033[1;36m' # Bold Cyan
INFO="${CYAN}"
EMPHASIZE="${B_CYAN}"
ERROR="${B_RED}"
WARNING="${B_YELLOW}"
PROMPT="${CYAN}"
INPUT="${OFF}"
function nextsuffix {
local name="$1"
local -i num=0
while [ -e "$name.0$num" ]; do
num+=1
done
printf "%s.0%d" "$name" "$num"
}
verify_not_root() {
if [ "$EUID" -eq 0 ]; then
echo -e "${ERROR}This script must not run as root"
exit -1
fi
}
check_klipper() {
if [ "$(sudo systemctl list-units --full -all -t service --no-legend | grep -F "klipper.service")" ]; then
echo -e "${INFO}Klipper service found"
else
echo -e "${ERROR}Klipper service not found! Please install Klipper first"
exit -1
fi
}
verify_home_dirs() {
if [ ! -d "${KLIPPER_HOME}" ]; then
echo -e "${ERROR}Klipper home directory (${KLIPPER_HOME}) not found. Use '-k <dir>' option to override"
exit -1
fi
if [ ! -d "${KLIPPER_CONFIG_HOME}" ]; then
if [ ! -d "${PRINTER_DATA_CONFIG_HOME}" ]; then
echo -e "${ERROR}Klipper config directory (${KLIPPER_CONFIG_HOME} or ${PRINTER_DATA_CONFIG_HOME}) not found. Use '-c <dir>' option to override"
exit -1
fi
KLIPPER_CONFIG_HOME="${PRINTER_DATA_CONFIG_HOME}"
fi
}
link_ercf_plugin() {
echo -e "${INFO}Linking ercf extension to Klipper..."
if [ -d "${KLIPPER_HOME}/klippy/extras" ]; then
for file in `cd ${SRCDIR}/extras ; ls *.py`; do
ln -sf "${SRCDIR}/extras/${file}" "${KLIPPER_HOME}/klippy/extras/${file}"
done
else
echo -e "${WARNING}ERCF modules not installed because Klipper 'extras' directory not found!"
fi
}
copy_template_files() {
if [ "${INSTALL_TEMPLATES}" -eq 0 ]; then
# Then check to see if we need to upgrade the current config files
upgrade_config_files
return
fi
# Generate sample colorselector, gate_status, endless_spool_groups based on number of gates
colorselector="colorselector: "
gate_status="gate_status: "
gate_material="gate_material: "
gate_color="gate_color: "
tool_to_gate_map="tool_to_gate_map: "
endless_spool_groups="endless_spool_groups: "
offset_x10=23
available=1
materials=(PLA PETG ABS PLA+ ABS ABS PLA ABS ASA)
colors=(red orange yellow green blue indigo violet ffffff black)
for (( i=0; i<=$(expr $num_gates - 1); i++ ))
do
mod=$(echo `expr $i % 9`)
if [ "${i}" -ne 0 ]; then
colorselector="${colorselector}, "
gate_status="${gate_status}, "
gate_material="${gate_material}, "
gate_color="${gate_color}, "
tool_to_gate_map="${tool_to_gate_map}, "
endless_spool_groups="${endless_spool_groups}, "
fi
colorselector="${colorselector}$(echo $offset_x10 | sed -e 's/.$/.&/;t' -e 's/.$/.0&/')"
gate_status="${gate_status}${available}"
gate_material="${gate_material}${materials[$mod]}"
gate_color="${gate_color}${colors[$mod]}"
tool_to_gate_map="${tool_to_gate_map}${i}"
endless_spool_groups="${endless_spool_groups}$(expr $i % 3 + 1)"
offset_x10=$(expr $offset_x10 + 210)
if [ "$(expr $i % 3)" -eq 2 ]; then
offset_x10=$(expr $offset_x10 + 51)
fi
available=0
done
if [ "${has_bypass}" -eq 1 ]; then
bypass_comment=""
else
bypass_comment="#"
fi
echo -e "${INFO}Copying configuration files to ${KLIPPER_CONFIG_HOME}"
for file in `cd ${SRCDIR} ; ls *.cfg`; do
dest=${KLIPPER_CONFIG_HOME}/${file}
if test -f $dest; then
next_dest="$(nextsuffix "$dest")"
echo -e "${INFO}Config file ${file} already exists - moving old one to ${next_dest}"
mv ${dest} ${next_dest}
fi
if [ "${file}" == "ercf_hardware.cfg" ]; then
if [ "${toolhead_sensor}" -eq 1 ]; then
magic_str1="## ERCF Toolhead sensor"
else
magic_str1="NO TOOLHEAD"
fi
uart_comment=""
if [ "${brd_type}" == "ERB" -o "${brd_type}" == "EASY-BRD-RP2040" ]; then
uart_comment="#"
fi
if [ "${sensorless_selector}" -eq 1 ]; then
cat ${SRCDIR}/${file} | sed -e "\
s/^#endstop_pin: \^{gear_endstop_pin}/endstop_pin: \^{gear_endstop_pin}/; \
s/^#diag_pin: \^{selector_diag_pin}/diag_pin: \^{selector_diag_pin}/; \
s/^#driver_SGTHRS: 75/driver_SGTHRS: 75/; \
s/^endstop_pin: \^{selector_endstop_pin}/#endstop_pin: \^{selector_endstop_pin}/; \
s/^#endstop_pin: tmc2209_selector_stepper/endstop_pin: tmc2209_selector_stepper/; \
s/^uart_address:/${uart_comment}uart_address:/; \
s/{brd_type}/${brd_type}/; \
" > ${dest}.tmp
else
# This is the default template config without sensorless selector homing enabled
cat ${SRCDIR}/${file} | sed -e "\
s/{brd_type}/${brd_type}/; \
s/^uart_address:/${uart_comment}uart_address:/; \
" > ${dest}.tmp
fi
# Now substitute pin tokens for correct brd_type
if [ "${brd_type}" == "unknown" ]; then
cat ${dest}.tmp | sed -e "\
s/{toolhead_sensor_pin}/${toolhead_sensor_pin}/; \
s%{serial}%${serial}%; \
/^${magic_str1} START/,/${magic_str1} END/ s/^#//; \
" > ${dest} && rm ${dest}.tmp
else
cat ${dest}.tmp | sed -e "\
s/{gear_uart_pin}/${PIN[$brd_type,gear_uart_pin]}/; \
s/{gear_step_pin}/${PIN[$brd_type,gear_step_pin]}/; \
s/{gear_dir_pin}/${PIN[$brd_type,gear_dir_pin]}/; \
s/{gear_enable_pin}/${PIN[$brd_type,gear_enable_pin]}/; \
s/{gear_diag_pin}/${PIN[$brd_type,gear_diag_pin]}/; \
s/{gear_endstop_pin}/${PIN[$brd_type,gear_endstop_pin]}/; \
s/{selector_uart_pin}/${PIN[$brd_type,selector_uart_pin]}/; \
s/{selector_step_pin}/${PIN[$brd_type,selector_step_pin]}/; \
s/{selector_dir_pin}/${PIN[$brd_type,selector_dir_pin]}/; \
s/{selector_enable_pin}/${PIN[$brd_type,selector_enable_pin]}/; \
s/{selector_diag_pin}/${PIN[$brd_type,selector_diag_pin]}/; \
s/{selector_endstop_pin}/${PIN[$brd_type,selector_endstop_pin]}/; \
s/{servo_pin}/${PIN[$brd_type,servo_pin]}/; \
s/{encoder_pin}/${PIN[$brd_type,encoder_pin]}/; \
s/{toolhead_sensor_pin}/${toolhead_sensor_pin}/; \
s%{serial}%${serial}%; \
/^${magic_str1} START/,/${magic_str1} END/ s/^#//; \
" > ${dest} && rm ${dest}.tmp
fi
elif [ "${file}" == "ercf_software.cfg" ]; then
cat ${SRCDIR}/${file} | sed -e "\
s%{klipper_config_home}%${KLIPPER_CONFIG_HOME}%g; \
" > ${dest}
else
# Other config files (not ercf_hardware.cfg, ercf_software.cfg, ercf_display_menu.cfg)
cp ${SRCDIR}/${file} ${dest}.tmp
cat ${dest}.tmp | sed -e "\
s/{sensorless_selector}/${sensorless_selector}/g; \
s/{clog_detection}/${clog_detection}/g; \
s/{endless_spool}/${endless_spool}/g; \
s/{servo_up_angle}/${servo_up_angle}/g; \
s/{servo_down_angle}/${servo_down_angle}/g; \
s/{calibration_bowden_length}/${calibration_bowden_length}/g; \
s/colorselector:.*/${colorselector}/; \
s/gate_status:.*/${gate_status}/; \
s/gate_material:.*/${gate_material}/; \
s/gate_color:.*/${gate_color}/; \
s/tool_to_gate_map:.*/${tool_to_gate_map}/; \
s/endless_spool_groups:.*/${endless_spool_groups}/; \
s/#bypass_selector:/${bypass_comment}bypass_selector:/; \
" > ${dest} && rm ${dest}.tmp
fi
done
if [ "${INSTALL_TEMPLATES}" -eq 1 ]; then
if [ "${add_includes}" -eq 1 ]; then
# Link in all includes if not already present
dest=${KLIPPER_CONFIG_HOME}/printer.cfg
if test -f $dest; then
next_dest="$(nextsuffix "$dest")"
echo -e "${INFO}Copying original printer.cfg file to ${next_dest}"
cp ${dest} ${next_dest}
if [ ${menu_12864} -eq 1 ]; then
i='\[include ercf_menu.cfg\]'
already_included=$(grep -c "${i}" ${dest} || true)
if [ "${already_included}" -eq 0 ]; then
sed -i "1i ${i}" ${dest}
fi
fi
for i in \
'\[include client_macros.cfg\]' \
'\[include ercf_software.cfg\]' \
'\[include ercf_parameters.cfg\]' \
'\[include ercf_hardware.cfg\]' ; do
already_included=$(grep -c "${i}" ${dest} || true)
if [ "${already_included}" -eq 0 ]; then
sed -i "1i ${i}" ${dest}
fi
done
else
echo -e "${WARNING}File printer.cfg file not found! Cannot include ERCF configuration files"
fi
fi
fi
}
# Save the user some time and attempt the upgrade of config files for them...
upgrade_config_files() {
echo -e "${INFO}Upgrading configuration files..."
hardware="ercf_hardware.cfg"
dest_hardware=${KLIPPER_CONFIG_HOME}/${hardware}
parameters="ercf_parameters.cfg"
dest_parameters=${KLIPPER_CONFIG_HOME}/${parameters}
encoder_pin="<FIXME>"
encoder_resolution="<FIXME>"
if test -f $dest_parameters; then
next_dest="$(nextsuffix "$dest_parameters")"
echo -e "${INFO}Pre upgrade config file ${dest_parameters} moved to ${next_dest} for reference"
cp ${dest_parameters} ${next_dest}
update_encoder=$(grep -c '\encoder_pin:' ${dest_parameters} || true)
if [ "${update_encoder}" -eq 1 ]; then
# These two settings have moved to ercf_hardware.cfg
encoder_pin=$(egrep 'encoder_pin:' ${dest_parameters} | awk '{ sub("\^", "") ; print $2 }')
encoder_resolution=$(egrep 'encoder_resolution:' ${dest_parameters} | awk '{ print $2 }')
# Comment out all old settings in ercf_parameters.cfg
echo -e "${WARNING}Upgrading ${dest_parameters} to remove legacy servo and encoder settings..."
cat ${dest_parameters} | sed -e " \
s/^encoder_pin:/#encoder_pin:/ ;
s/^encoder_resolution:/#encoder_resolution:/ ;
s/^extra_servo_dwell_up:/#extra_servo_dwell_up:/ ;
s/^extra_servo_dwell_down:/#extra_servo_dwell_down:/ ;
" > ${dest_parameters}.encoder_upgrade && mv ${dest_parameters}.encoder_upgrade ${dest_parameters}
fi
fi
if test -f $dest_hardware; then
next_dest="$(nextsuffix "$dest_hardware")"
echo -e "${INFO}Pre upgrade config file ${dest_hardware} moved to ${next_dest} for reference"
cp ${dest_hardware} ${next_dest}
update_servo=$(grep -c '\[servo ercf_servo\]' ${dest_hardware} || true)
if [ "${update_servo}" -eq 1 ]; then
echo -e "${WARNING}Upgrading ${dest_hardware} for new ercf_servo..."
cat ${dest_hardware} | sed -e " \
s/^\[servo ercf_servo\]/\[ercf_servo ercf_servo\]/ ;
" > ${dest_hardware}.servo_upgrade
else
# Servo already upgraded or can't upgrade
cp ${dest_hardware} ${dest_hardware}.servo_upgrade
fi
# This is a little difficult to cleanly update, so try a couple of strategies
update_encoder=$(grep -c '\[filament_motion_sensor encoder_sensor\]' ${dest_hardware}.servo_upgrade || true)
if [ "${update_encoder}" -eq 1 ]; then
magic_str2="# ERCF Clog detection"
echo -e "${WARNING}Upgrading ${dest_hardware} for new ercf_encoder..."
cat ${dest_hardware}.servo_upgrade | sed -e " \
/${magic_str2} START/,/${magic_str2} END/d; \
/\[duplicate_pin_override\]/d; \
/pins:/d; \
/\[filament_motion_sensor encoder_sensor\]/,+6 d; \
" > ${dest_hardware} && rm ${dest_hardware}.servo_upgrade
# Finally add on the new encoder section
cat << EOF >> ${dest_hardware}
## ENCODER -----------------------------------------------------------------------------------------------------------------
## The encoder_resolution is determined by running the ERCF_CALIBRATE_ENCODER. Be sure to read the manual
[ercf_encoder ercf_encoder]
encoder_pin: ^${encoder_pin} # EASY-BRD: ^ercf:PA6, Flytech ERB: ^ercf:gpio22
encoder_resolution: ${encoder_resolution} # Set AFTER 'rotation_distance' is tuned for gear stepper (see manual)
extruder: extruder # The extruder to track with for runout/clog detection
# These are advanced but settings for Automatic clog/runout detection mode. Make sure you understand or ask questions on Discord
desired_headroom: 5.0 # The runout headroom that ERCF will attempt to maintain (closest ERCF comes to triggering runout)
average_samples: 4 # The "damping" effect of last measurement. Higher value means clog_length will be reduced more slowly
EOF
else
# Encoder already upgraded or can't upgrade
mv ${dest_hardware}.servo_upgrade ${dest_hardware}
fi
fi
}
install_update_manager() {
echo -e "${INFO}Adding update manager to moonraker.conf"
if [ -f "${KLIPPER_CONFIG_HOME}/moonraker.conf" ]; then
update_section=$(grep -c '\[update_manager ercf-happy_hare\]' \
${KLIPPER_CONFIG_HOME}/moonraker.conf || true)
if [ "${update_section}" -eq 0 ]; then
echo "" >> ${KLIPPER_CONFIG_HOME}/moonraker.conf
while read -r line; do
echo -e "${line}" >> ${KLIPPER_CONFIG_HOME}/moonraker.conf
done < "${SRCDIR}/moonraker_update.txt"
echo "" >> ${KLIPPER_CONFIG_HOME}/moonraker.conf
restart_moonraker
else
echo -e "${INFO}[update_manager ercf] already exist in moonraker.conf - skipping install"
fi
else
echo -e "${WARNING}Moonraker.conf not found!"
fi
}
restart_klipper() {
echo -e "${INFO}Restarting Klipper..."
sudo systemctl restart klipper
}
restart_moonraker() {
echo -e "${INFO}Restarting Moonraker..."
sudo systemctl restart moonraker
}
prompt_yn() {
while true; do
read -p "$@ (y/n)?" yn
case "${yn}" in
Y|y|Yes|yes)
echo "y"
break;;
N|n|No|no)
echo "n"
break;;
*)
;;
esac
done
}
questionaire() {
if [ "${INSTALL_TEMPLATES}" -eq 1 ]; then
echo
echo -e "${INFO}Let me see if I can help you with initial config (you will still have some manual config to perform)...${INPUT}"
echo
brd_type="unknown"
yn=$(prompt_yn "Are you using the EASY-BRD or Fysetc Burrows ERB controller?")
case $yn in
y)
echo -e "${INFO}Great, I can setup almost everything for you. Let's get started"
serial=""
echo
for line in `ls /dev/serial/by-id | egrep "Klipper_samd21|Klipper_rp2040"`; do
if echo ${line} | grep --quiet "Klipper_samd21"; then
brd_type="EASY-BRD"
else
echo -e "${PROMPT}You seem to have a ${EMPHASIZE}RP2040-based${PROMPT} controller serial port.${INPUT}"
yn=$(prompt_yn "Are you using the Fysetc Burrows ERB controller?")
case $yn in
y)
brd_type="ERB"
;;
n)
brd_type="EASY-BRD-RP2040"
;;
esac
fi
echo -e "${PROMPT}This looks like your ${EMPHASIZE}${brd_type}${PROMPT} controller serial port. Is that correct?${INPUT}"
yn=$(prompt_yn "/dev/serial/by-id/${line}")
case $yn in
y)
serial="/dev/serial/by-id/${line}"
break
;;
n)
brd_type="unknown"
;;
esac
done
if [ "${serial}" == "" ]; then
echo
echo -e "${PROMPT}Couldn't find your serial port, but no worries - I'll configure the default and you can manually change later${INPUT}"
yn=$(prompt_yn "Setup for EASY-BRD? (Answer 'N' for Fysetc Burrows ERB)")
case $yn in
y)
yn1=$(prompt_yn "EASY-BRD with SAMD21 (default)? (Answer 'N' for EASY-BRD with RP2040)")
case $yn1 in
y)
brd_type="EASY-BRD"
;;
n)
brd_type="EASY-BRD-RP2040"
;;
esac
;;
n)
brd_type="ERB"
;;
esac
serial='/dev/ttyACM1 # Config guess. Run ls -l /dev/serial/by-id and set manually'
fi
echo
echo -e "${WARNING}Board Type: ${brd_type}"
echo
echo -e "${PROMPT}Sensorless selector operation? This allows for additional selector recovery steps but disables the 'extra' input on the EASY-BRD.${INPUT}"
yn=$(prompt_yn "Enable sensorless selector operation")
case $yn in
y)
if [ "${brd_type}" == "EASY-BRD" ]; then
echo
echo -e "${WARNING} IMPORTANT: Set the J6 jumper pins to 2-3 and 4-5, i.e. .[..][..] MAKE A NOTE NOW!!"
fi
sensorless_selector=1
;;
n)
if [ "${brd_type}" == "EASY-BRD" ]; then
echo
echo -e "${WARNING} IMPORTANT: Set the J6 jumper pins to 1-2 and 4-5, i.e. [..].[..] MAKE A NOTE NOW!!"
fi
sensorless_selector=0
;;
esac
;;
n)
easy_brd=0
echo -e "${INFO}Ok, I can only partially setup non EASY-BRD/ERB installations, but lets see what I can help with"
serial=""
echo
for line in `ls /dev/serial/by-id`; do
echo -e "${PROMPT}Is this the serial port to your ERCF mcu?${INPUT}"
yn=$(prompt_yn "/dev/serial/by-id/${line}")
case $yn in
y)
serial="/dev/serial/by-id/${line}"
break
;;
n)
;;
esac
done
if [ "${serial}" = "" ]; then
echo -e "${INFO}Couldn't find your serial port, but no worries - I'll configure the default and you can manually change later as per the docs"
serial='/dev/ttyACM1 # Config guess. Run ls -l /dev/serial/by-id and set manually'
fi
echo
echo -e "${PROMPT}Sensorless selector operation? This allows for additional selector recovery steps${INPUT}"
yn=$(prompt_yn "Enable sensorless selector operation")
case $yn in
y)
sensorless_selector=1
;;
n)
sensorless_selector=0
;;
esac
;;
esac
num_gates=9
echo
echo -e "${PROMPT}How many gates (selectors) do you have (3, 6, 9, 12)?${INPUT}"
while true; do
read -p "Number of gates? " num_gates
if ! [ "${num_gates}" -ge 1 ] 2> /dev/null ;then
echo -e "${INFO}Positive integer value only"
else
break
fi
done
echo
echo -e "${PROMPT}Have you built with a selector bypass? (in one of the selector separators)${INPUT}"
yn=$(prompt_yn "Selector bypass")
case $yn in
y)
has_bypass=1
echo -e "${INFO} NOTE: You will need to set the bypass selector offset manually"
;;
n)
has_bypass=0
;;
esac
echo
echo -e "${PROMPT}Do you have a toolhead sensor you would like to use? If reliable this provides the smoothest and most reliable loading and unloading operation${INPUT}"
yn=$(prompt_yn "Enable toolhead sensor")
case $yn in
y)
toolhead_sensor=1
echo -e "${PROMPT} What is the mcu pin name that your toolhead sensor is connected too?"
echo -e "${PROMPT} If you don't know just hit return, I can enter a default and you can change later${INPUT}"
read -p " Toolhead sensor pin name? " toolhead_sensor_pin
if [ "${toolhead_sensor_pin}" = "" ]; then
toolhead_sensor_pin="{dummy_pin_must_set_me}"
fi
;;
n)
toolhead_sensor=0
toolhead_sensor_pin="{dummy_pin_must_set_me}"
;;
esac
echo
echo -e "${PROMPT}Using default MG-90S servo? (Answer 'N' for Savox SH0255MG, you can always change it later)${INPUT}"
yn=$(prompt_yn "MG-90S Servo?")
case $yn in
y)
servo_up_angle=30
servo_down_angle=140
;;
n)
servo_up_angle=140
servo_down_angle=30
;;
esac
echo
echo -e "${PROMPT}Clog detection? This uses the ERCF encoder movement to detect clogs and can call your filament runout logic${INPUT}"
yn=$(prompt_yn "Enable clog detection")
case $yn in
y)
clog_detection=1
echo -e "${PROMPT} Would you like ERCF to automatically adjust clog detection length (recommended)?${INPUT}"
yn=$(prompt_yn " Automatic")
if [ "${yn}" == "y" ]; then
clog_detection=2
fi
;;
n)
clog_detection=0
;;
esac
echo
echo -e "${PROMPT}EndlessSpool? This uses filament runout detection to automate switching to new spool without interruption${INPUT}"
yn=$(prompt_yn "Enable EndlessSpool")
case $yn in
y)
endless_spool=1
if [ "${clog_detection}" -eq 0 ]; then
echo
echo -e "${WARNING} NOTE: I've re-enabled clog detection which is necessary for EndlessSpool to function"
clog_detection=2
fi
;;
n)
endless_spool=0
;;
esac
echo
echo -e "${PROMPT}What is the length of your reverse bowden tube in mm?"
echo -e "${PROMPT}(This is just to speed up calibration and needs to be approximately right but not longer than the real length)${INPUT}"
while true; do
read -p "Reverse bowden length in mm? " calibration_bowden_length
if ! [ "${calibration_bowden_length}" -ge 1 ] 2> /dev/null ;then
echo -e "${INFO}Positive integer value only"
else
break
fi
done
echo
menu_12864=0
echo -e "${PROMPT}Finally, would you like me to include all the ERCF config files into your printer.cfg file${INPUT}"
yn=$(prompt_yn "Add include?")
case $yn in
y)
add_includes=1
echo -e "${PROMPT} Would you like to include Mini 12864 menu configuration extension for ERCF${INPUT}"
yn=$(prompt_yn " Include menu")
case $yn in
y)
menu_12864=1
;;
n)
menu_12864=0
;;
esac
;;
n)
add_includes=0
;;
esac
echo
echo -e "${INFO}"
echo " vvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvv"
echo
echo " NOTES:"
echo " What still needs to be done:"
if [ "${brd_type}" == "unknown" ]; then
echo " * Edit *.cfg files and substitute all \{xxx\} tokens to match or setup"
echo " * Review all pin configuration and change to match your mcu"
else
echo " * Tweak motor speeds and current, especially if using non BOM motors"
echo " * Adjust motor direction with '!' on pin if necessary. No way to know here"
fi
echo " * Adjust your config for loading and unloading preferences"
echo " * Adjust toolhead distances 'home_to_extruder' for your particular setup"
echo
echo " Advanced:"
echo " * Tweak configurations like speed and distance in ercf_parameter.cfg"
echo
echo " Good luck! ERCF is complex to setup. Remember Discord is your friend.."
echo
echo " ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^"
echo
fi
}
usage() {
echo -e "${EMPHASIZE}"
echo "Usage: $0 [-k <klipper_home_dir>] [-c <klipper_config_dir>] [-i]"
echo
echo "-i for interactive"
echo
exit 1
}
# Force script to exit if an error occurs
set -e
clear
# Find SRCDIR from the pathname of this script
SRCDIR="$( cd "$( dirname "${BASH_SOURCE[0]}" )"/ && pwd )"
INSTALL_TEMPLATES=0
INSTALL_KLIPPER_SCREEN_ONLY=0
while getopts "k:c:i" arg; do
case $arg in
k) KLIPPER_HOME=${OPTARG};;
c) KLIPPER_CONFIG_HOME=${OPTARG};;
i) INSTALL_TEMPLATES=1;;
*) usage;;
esac
done
verify_not_root
verify_home_dirs
check_klipper
questionaire
link_ercf_plugin
copy_template_files
install_update_manager
restart_klipper
echo -e "${EMPHASIZE}"
echo "Done. Enjoy ERCF (and thank you Ette for a wonderful design)..."
echo -e "${INFO}"
echo '(\_/)'
echo '( *,*)'
echo '(")_(") ERCF Ready'
echo