Skip to content

Latest commit

 

History

History
75 lines (50 loc) · 3.07 KB

Proxy Arp.md

File metadata and controls

75 lines (50 loc) · 3.07 KB

Introduction

The scope of this document is to provide the requirements and a high-level design proposal for Proxy ARP support.

Requirements

The following are the high level requirements when an interface is enabled with "proxy_arp"

  1. Proxy arp shall be set for the interface in kernel
  2. Hardware ARP packet action for that interface must be trap to CPU and not flooded/forwarded in hardware.

When the interface is deleted, the corresponding configurations must be removed. A VS and sonic-mgmt test is required to validate the configuration

Design Proposal

The design is intended to have a generic approach for proxy-arp feature. A user can set an attribute "proxy_arp" to the config_db entry for INTERFACE table entry. The default value if not specified would be "disabled"

The schema change for proxy-arp is as below:

VLAN_INTERFACE|{{intf_name}} 
    "vnet_name": {{vnet_name}}
    "proxy_arp": "enabled"
          
VLAN_INTERFACE|{{intf_name}}|{{prefix}}  
    { }
; Defines Interface table schema

key             = INTERFACE:name         ; Same as existing
; field
vnet_name       = vnet_name              ; Same as existing
proxy_arp       = "enabled" / "disabled" ; Default "disabled" (Optional attribute)

When proxy_arp is enabled for an interface, e.g

"VLAN_INTERFACE": {
    "Vlan2000": {
         "vnet_name": "Vnet_3000"
         "proxy_arp": "enabled"
 }

the following kernel param must be set to 1:

/proc/sys/net/ipv4/conf/Vlan2000/proxy_arp_pvlan

and SAI configuration for SAI_VLAN_ATTR_BROADCAST_FLOOD_CONTROL_TYPE must be set to SAI_VLAN_FLOOD_CONTROL_TYPE_NONE

Flows

The following flow diagram captures two example, one for user configuration and another for vnet interfaces

Kernel config

SAI config

For requirement #2, the proposal is to disable flooding for the specific Vlan so that ARP packets shall not get flooded in hardware. By default in Sonic, it is a copy action for ARP packets which means, packets gets flooded in hardware. In the event of enabling proxy-arp, flooding must be disabled. This enables the switch to respond to ARP requests within this subnet to be responded with its SVI mac. Intforch must invoke "Vlan flood" disable during the RIF creation based on "prxoy_arp" attribute.

Additional Notes

  1. The flooding is disabled only for those interfaces that has proxy_arp setting. The implementation shall not modify the existing behavior and shall be backward compatible.
  2. VS test can be added to existing test_vnet.py to verify the kernel/SAI configuration.
  3. Proxy ND is not planned as part of this feature but can be extended in future based on the same approach
  4. /proc/sys/net/ipv4/conf/Vlan2000/proxy_arp is not required to be set.
  5. For non-Vlan interfaces, proxy_arp shall be set in kernel but no configuration is applied to SAI