Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathgpc.m
35 lines (27 loc) · 893 Bytes
/
gpc.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%%%%% Autor: Anhelina Kyrylova %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%% MPC controller using the GPC settings
Kp=1.5;
T1=1.5;
G = Kp * tf(1, [T1 1])
% Discretize the plant with sample time
Ts = 0.3;
Gd = c2d(G, Ts)
% Create a GPC settings structure.
GPCoptions = gpc2mpc;
% Hu
GPCoptions.NU = 2;
% Hp
GPCoptions.N2 = 1;
GPCoptions.N2 = 3;
% R
GPCoptions.Lam = 0.5;
GPCoptions.T = [1 -0.8];
% Convert GPC to an MPC controller.
mpc = gpc2mpc(Gd, GPCoptions);
% Simulate for 50 steps with unmeasured disturbance between
% steps 26 and 28, and reference signal of 0.
SimOptions = mpcsimopt(mpc)
SimOptions.UnmeasuredDisturbance = [zeros(25,1);-0.1*ones(3,1); 0];
sim(mpc, 50, 0, SimOptions);